Vista de página 15
User manual for the ZEN 3-channel X-LMS controller Soft dB inc.
3.2 Description of the control algorithm for the coupled case
Figure 9 shows a schematic of the coupled version of the controller. Unlike Figure 5
which shows the uncoupled version, the secondary cross-paths CxEy (xy) are now
included. This implies three optimizations for each channel using all error signals. This
algorithm requires three times the computation time of the uncoupled version.
Figure 9: Schematic for the coupled version of the control algorithm
The X-LMS optimization for a specific channel is computed in three steps with these
equations:
11
,
EOutCEMuWxWx xnormxn
n
+=
22
,,,
EOutCEMuWxWx xnormx
nn
+=
33
,,
1 EOutCEMuWxWx xnormx
n
n +=+
Where OutCxEy is the output of the secondary control path filter CxEy.