Soft-db Opus Suite Building Acoustics Module Airborne Soun Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Áudio Soft-db Opus Suite Building Acoustics Module Airborne Soun. Soft dB Opus Suite Building Acoustics Module Airborne Sound Isolation between Rooms ASTM E 336_ISO 140-4 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Opus Suite
Building Acoustics Module
Airborne Sound Isolation between Rooms
ASTM E 336 / ISO 140-4
User Guide – v1.1
2012-12-06
Alto 6-Channel
Concerto 4-Channel
I-Track 6-Channel
Compatible Hardware:
Soft dB Inc.
1040,
Belvedere Avenue, Suite 215
Quebec (Quebec) Canada G1S 3G3
Toll free: 1
-866-686-0993 (USA and Canada)
E-mail: contact@softdb.com
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - Opus Suite

Opus Suite Building Acoustics Module Airborne Sound Isolation between Rooms ASTM E 336 / ISO 140-4 User Guide – v1.1 2012-12-06 Alto 6-Channel Conce

Página 2 - CONTENTS

9 Step 3 Do a Reverberation Measurement To proceed to a reverberation measurement, select an element to measure in the table of the main panel and

Página 3 - 1 Introduction

10 Step 4 Analyze the results The result tab displays the results of the sound transmission class to the evaluated partitions. The measurements can

Página 4

11 5 Main Interface Figure 1: Main interface Main controls and indicators Standard used for the STC evaluation. The standard can be changed at any

Página 5

12 File Menu New Creates a brand new measurement session. Open Opens a previous measurement file. Save Saves the current measurement into the speci

Página 6

13 6 Setup Interface Figure 2: Setup interface Input Setup The input channel used for the measurements The available input types are AC and ICP s

Página 7 - 4 Quick Start

14 Level Measurement Setup The unit can be used to generate a pink noise or a white noise. The output signal is balanced on output 1 and output 2. I

Página 8

15 6.1 Sensor Calibration The input sensitivity can be calibrated using the calibration function and a sensor calibrator. Click the button on the S

Página 9

16 7 Measurements tab The Measurements tab can be divided in three parts. The partition information is in upper left corner. Just under is the t

Página 10

17 If an element of the table is selected, the measurement interface will be called (see the following subsections). Click this button to delete th

Página 11

18 Details of the selected element in the table Name and global level of the selected element. Description of the selected element Spectrum graph o

Página 12 - 5 Main Interface

i CONTENTS 1 Introduction ...

Página 13

19 7.1 Level Measurement Interface Level Measurement controls The Start/Pause button starts/pauses the average measurements. The measurement wi

Página 14 - 6 Setup Interface

20 7.2 Reverberation Measurement Interface Figure 3: Reverberation Measurement Interface Reverberation Measurement controls The Run/Pause butto

Página 15

21 Once the measurement is acceptable, press the Accept button to return to the main interface. 7.2.1 Reverberation: Time Decay This display shows

Página 16 - 6.1 Sensor Calibration

22 7.2.2 Reverberation: Spectrum This display shows a selected result for each frequency band and global using a bar graph. To select a frequency or

Página 17 - 7 Measurements tab

23 7.2.3 Reverberation: Data This display shows all data for all frequency bands and global in a table form.

Página 18

24 8 Result tab Figure 5: Result tab The Result tab of the main interface contains the table of result (left side) and the details (right side). Th

Página 19

25 Details of the selected element in the table Name and value of the selected element. Description of the selected element Spectrum graph of the s

Página 20

26 9 Comments tab The Comments tab on the main panel can be used as a general note pad that will be saved along with the measurement data.

Página 21

27 10 Explorer Dialog Explorer Window Controls and Indicators File/Folder Operators • Go to parent directory • Open directory • Create new folde

Página 22

28 11 File Manager The File manager is used to perform most file operations: • Navigate the directory structure • Create folders • Rename files a

Página 23

2 1 Introduction Congratulations on your purchase of the Opus Suite STC module. The Opus Software Suite is a Sound and Vibration software that c

Página 24 - 7.2.3 Reverberation: Data

29 Directory Path Displays the path of the active directory. Shortcuts Allows easy access to common directories. When the File Manager is used on a s

Página 25 - 8 Result tab

30 Appendix 1: Concerto Hardware Connections 4 Inputs Mic Stand DC in ¼ 20 insert Power-on button Second Battery 2 Outputs USB port Right click

Página 26

31 Power on/off Turn On Press the trigger button located at the back of the unit This key has two (2) functions: 1. To turn the unit ON. 2. Start

Página 27 - 9 Comments tab

32 Power Reset If the Concerto happens to crash and it is not possible to take back the control, a power reset might be necessary. To complete the po

Página 28 - 10 Explorer Dialog

33 Inputs and Signal Processing Specifications (Embedded Signal Ranger MK3 DSP Board) DSP Processor Texas Instruments TMS320C6424 Inputs 4 Outputs 2

Página 29 - 11 File Manager

34 Appendix 2: 1/3 Octave Filters – IEC 61260 Class 1/ANSI S1.11 1/3 Octave Filters The 1/3 octave filters are computed at low-level in real time (at

Página 30

35 Shape Test Numerical Results at 1 kHz The following table presents the numerical results of the shape test at 1 kHz: Frequency (Hz) Low limit (dB)

Página 31

36 1/3 Octave Filter Linearity The linearity of the 1/3-octave filter has been measured for both ranges (low and high). The experimentation is done w

Página 32

37 Frequency (Hz) Saturation Level (dB) Minimum Linear Level (dB) Linear Dynamic Range (dB) Noise Floor (dB) 12500 120.5 27.0 93.5 17.5 16000 120.5

Página 33

38 Frequency (Hz) Saturation Level (dB) Minimum Linear Level (dB) Linear Dynamic Range (dB) Noise Floor (dB) 10000 132.5 33.5 99.0 23.5 12500 132.5

Página 34

3 2 Compatible Hardware Every hardware option has an embedded state of the art Soft dB SR-MK3 DSP board allowing real-time and precise measurement w

Página 35 - Attenuation dB

39 Summation Test (High Range Case)-0.5-0.4-0.3-0.2-0.100.10.20.30.40.510 1001000 10000 100000Frequency (Hz)Amplitude dB

Página 36

4 3 Opus Environment The Concerto unit comes equipped with the Opus Environment. This environment acts as a main interface that gives access to t

Página 37

5 Modules The modules buttons will launch the associated module. When a module is opened, a license verification check is done. If no license is foun

Página 38

6 4 Quick Start The STC module is part of the Building Acoustic. It can be accessed in the Building Acoustic menu of the Opus Suite panel. Measureme

Página 39 - Amplitude dB

7 Step 1 Setup the unit Click on the button to access the setup interface. The parameter should typically be set as shown on figure above. Before

Página 40

8 Step 2 Do a Level Measurement To proceed to a measurement, select an element to measure in the table of the main panel and click the button to

Comentários a estes Manuais

Sem comentários